Contact Us

GPS SERIES · POINT-OF-ENTRY

GPS Whole-House Filtration & UVC LED Disinfection

Combine sediment filtration, carbon treatment and UVC LED disinfection at the main water inlet. GPS brings replaceable filter cartridges and the AGLED-12G unit together on one mounting bracket, with four configurations for residential water-treatment projects.

4 models 10- / 20-inch cartridges
3 / 4 stages Including UVC LED
AGLED-12G Integrated disinfection unit
1 inch System inlet / outlet

TREATMENT ROLES

Filtration and UVC disinfection, brought together

01

One mounting assembly

Filter housings and the UVC LED unit share a support bracket, bringing the treatment stages together at the main inlet.

02

Filtration before UVC

A polypropylene (PP) sediment cartridge comes first, followed by carbon-block (CTO) filtration. GPS-104 and GPS-204 add granular activated carbon (GAC) before CTO. Carbon-treatment goals include chlorine, taste and odour reduction; performance and capacity depend on the selected cartridge.

03

Flow-activated UVC LED treatment

The integrated AGLED-12G unit provides UVC LED disinfection after filtration, with white, blue and red indicators for standby, operation and fault.

04

Replaceable filter cartridges

The 10 × 4.5-inch and 20 × 4.5-inch cartridge formats support routine filter replacement. The open bracket leaves the housings accessible for service.

GPS-103 / GPS-203

  1. Fibrous sediment-filter media reference
    PPSediment
  2. Activated-carbon material reference for the CTO stage
    CTOCarbon block
  3. AGLED-12G UVC LED disinfection unit
    UVC LEDDisinfection

GPS-104 / GPS-204

  1. Fibrous sediment-filter media reference
    PPSediment
  2. Granular activated-carbon media reference
    GACGranular carbon
  3. Activated-carbon material reference for the CTO stage
    CTOCarbon block
  4. AGLED-12G UVC LED disinfection unit
    UVC LEDDisinfection

MODEL SELECTION

Choose your cartridge size and filter combination

All four GPS models use the same AGLED-12G UVC LED unit. The differences are cartridge size and the addition of a GAC filter stage.

Compare cartridge size and treatment stages. Swipe the table to view all four models →

Four-model GPS configuration comparison
ConfigurationGPS-103GPS-104GPS-203GPS-204
Cartridge size10 × 4.5 in10 × 4.5 in20 × 4.5 in20 × 4.5 in
Filter housings2323
Treatment stages, including UVC3434
Filter combinationPP + CTOPP + GAC + CTOPP + CTOPP + GAC + CTO
QuotationRequest a GPS-103 Quote →Request a GPS-104 Quote →Request a GPS-203 Quote →Request a GPS-204 Quote →
  1. 01

    Start with the available mounting height

    Compare GPS-103 and GPS-104 for 10-inch cartridges, or GPS-203 and GPS-204 for 20-inch cartridges. Check the selected model’s overall height and the space needed below it to remove the housings. Match flow and cartridge capacity using the specified filter data.

  2. 02

    Decide whether you need an additional carbon stage

    GPS-103 and GPS-203 combine sediment and carbon-block filtration. Compare GPS-104 and GPS-204 when your treatment plan calls for a separate granular-carbon stage for chlorine, taste or odour control. Check the proposed cartridge’s capacity and pressure drop at your target flow before choosing the additional stage.

  3. 03

    Need help choosing?

    Send your water source, expected peak flow and available installation space. Include a water report if you have one.

ENGINEERING DATA

GPS system and UVC unit specifications

01 · GPS system

Inlet / outlet
1-inch stainless-steel connections
Operating water temperature
2–40°C
Ambient temperature
2–40°C
Support bracket
Powder-coated iron

02 · Integrated AGLED-12G unit

DC input
24 V DC
Rated electrical power
16 W
Listed unit flow rate
12 GPM / approximately 45 L/min
Minimum unit flow
2.5 L/min
Maximum unit pressure
8 bar
LED rated life
L70, 5,000 operating hours

Source: AGLED-12G owner’s manual ↗. Unit ratings describe AGLED-12G; complete GPS flow, pressure drop and pressure limits depend on the selected assembly and cartridges.

03 · UVC unit materials

Unit housing
SUS304 stainless steel
Fixed water-contact materials
SUS304, POM, quartz glass and EPDM

04 · Water entering the UVC unit

Recommended UVT
Above 93%
Turbidity
Below 1 NTU
Iron
Below 0.3 mg/L
Hardness
Below 120 mg/L
Manganese
Below 0.05 mg/L
Tannins
Below 0.1 mg/L

These are the manual’s operating water-quality guidelines. See the manual for its separate warranty conditions.

Planning an installation? Ask for the selected model’s dimensions, cartridge-removal clearance, flow / pressure-drop data and supply specification.

INSIDE THE GPS SYSTEM

Designed for connection and routine access

The photographs below show the GPS series. Use the model images above to compare the four configurations.

Real GPS series close-up showing the integrated UVC unit, flexible connection and flow-direction label

Water connections

Follow the inlet / outlet markings and flow direction. Match the thread specification and fittings to the selected model.

Real GPS series rear view with bracket mounting slots and filter housings

Filter access

Keep the bracket fixings accessible and leave space below the housings for cartridge replacement.

INTEGRATED AGLED-12G

Integrated AGLED-12G unit

The UVC LED unit follows the filter stages and operates in response to water flow.

The indicators show operating status. They do not measure UV intensity or disinfection performance.

Explore the AGLED-12G Unit ↗

White · Standby

The unit is in standby.

Blue · Operating

The unit is operating.

Red · Fault

Follow the manual and contact technical support.

INSTALLATION & MAINTENANCE

Install at the main inlet. Plan access for service.

Position GPS before the household plumbing branches. Follow the supplied installation instructions for mounting, plumbing, isolation and electrical connection.

01
CONNECTION PLANNINGWhole-house point-of-entry layout
Conceptual installation: incoming pipe and isolation valve, optional pretreatment vessel, model-derived GPS-204 assembly at the main inlet, whole-house outlets and approved power supply

Planning layout; not to scale. Confirm actual ports and supplied accessories. Open full size ↗

Before installation

Check the supporting surface, mounting dimensions, pipe connections and flow direction. Allow space for housing removal and UVC unit service, and use the approved power adapter and plug for your market.

Routine filter service

  1. Isolate the water supply, disconnect power and release pressure before servicing.
  2. Replace cartridges according to their instructions, water quality and usage.
  3. Reassemble and flush as directed, check for leaks and verify the operating indicator.

UVC unit replacement

The AGLED-12G owner’s manual recommends replacing the complete unit every 3 years. Record the installation date. Internal LED parts are not user-replaceable; contact technical support for faults or replacement.

The LED’s L70 rating of 5,000 operating hours describes output declining to 70% of its initial value. It is separate from the manual’s 3-year unit-replacement recommendation.

Open the AGLED-12G Owner’s Manual ↗

TESTING & TECHNICAL RESOURCES

Test evidence for the integrated UVC unit

The AGLED-12G unit used in GPS was tested by SGS for total-coliform removal at the start of operating life.

SGS TEST REPORT>99.999%

Total-coliform removal
AGLED-12G test sample

Read the SGS Test Report ↗

Sample and test conditions

Report / date
NBF25-0021833-01 · 20 October 2025
Sample model
AGLED-12G · one set
Flow recorded in the report
50 L/min
Challenge strain
Escherichia coli ATCC 25922
Test item
Total-coliform removal at the start of operating life
Influent / effluent
1.1 × 10⁶ CFU/100 mL / <1 CFU/100 mL

This result applies to the sample and conditions in the report. The 50 L/min test condition is separate from the manual’s listed unit flow rate of 12 GPM (approximately 45 L/min); it does not establish the rated flow or disinfection result of a complete GPS assembly.

GPS · CONFIGURATION OVERVIEW

GPS Configuration Overview

Compare the four cartridge configurations and shared system information.

Open overview ↗
AGLED-12G · UNIT MANUAL

AGLED-12G Owner’s Manual

Review installation, operating water quality, indicators and service guidance.

Open unit manual ↗
AGLED-12G · TEST REPORT

Original SGS Report

View the tested sample, method, conditions and results.

Open SGS report ↗

FREQUENTLY ASKED QUESTIONS

GPS selection questions

Can GPS be used with municipal or well water?

Start with the incoming water quality. GPS combines sediment and carbon filtration with UVC LED disinfection. Well water or other untreated sources may need additional treatment to meet the UVC unit’s water-quality requirements. A water report helps identify what is needed before GPS.

How should I choose between 10-inch and 20-inch cartridges?

Start with the available mounting height and cartridge-removal space, then compare the specified cartridges’ capacity and pressure drop at your required flow. GPS-103 and GPS-104 use 10-inch cartridges; GPS-203 and GPS-204 use 20-inch cartridges. Cartridge length alone does not set the complete system’s flow rating.

What changes when I choose GPS-104 or GPS-204?

These models add a GAC cartridge between PP and CTO for an additional carbon-treatment stage. All four GPS models use the same AGLED-12G UVC LED unit. Select GAC according to the water-treatment objective and the proposed cartridge’s specifications.

What should I check for low-flow use?

The AGLED-12G manual lists a minimum unit flow of 2.5 L/min. Share the lowest expected draw as well as peak demand so the flow-activation settings can be checked for your installation. The minimum-flow specification does not define the sensor’s switching threshold.

What should I send to request a quote?

Tell us the model if known, target market and estimated quantity. For selection support, add the water source, expected peak and minimum flow, and available installation space. A water report is helpful if available.

GPS AND VPS

Comparing UVC service options?

GPS uses the integrated AGLED-12G unit, which is replaced as a complete unit. VPS uses the AGLED-40012 platform with a separate driver and a serviceable LED-module design.

Explore VPS Systems ↗

GPS QUOTATION & SELECTION

Request a GPS quote or model recommendation

Choose a model or select “Help me choose.” Tell us your target market, estimated quantity and what you need to know. Add water and installation details if available.
  • Water source & UVT
  • Peak & minimum flow
  • Connections & power
  • Installation space

Name, email, company and WhatsApp / Phone are required. All other fields are optional.

Add water and installation details (optional)

By submitting this form, you agree that Agua Topone may use the information to respond to your inquiry. See our Privacy Policy.