Whole-house POE
A final disinfection stage where realistic simultaneous demand stays within the selected model basis.
HIGH-FLOW POE UVC LED SYSTEM · 12 GPM
A 24 V DC high-flow module for whole-house and light-commercial systems.
AGLED-12G combines a 12 GPM flow class, G1 connection and 24 V DC architecture for whole-house and light-commercial water-treatment projects.
PRODUCT ROLE
The model provides a UVC disinfection stage for pretreated whole-house and light-commercial water paths. Filtration, UVT, turbidity, iron, hardness and realistic simultaneous demand remain separate design inputs.
APPLICATION FIT
A final disinfection stage where realistic simultaneous demand stays within the selected model basis.
Pretreated drinking-water lines with defined peak flow, water quality and duty cycle.
Our team matches the model with the water analysis and required sediment, iron or other pretreatment.
Integration into equipment with confirmed G1 connections, 24 V DC supply and service plan.
ENGINEERING DATA
The current drawing, datasheet and manual are available for project review. Our team will align them with the quoted configuration.
Hydraulic & mechanical
Electrical & optical
| No. | Parameter | Symbol | Value | Unit |
|---|---|---|---|---|
| 01 | Input voltage | VIN | 24 | V DC |
| 02 | Output current | IOUT | 600 | mA |
| 03 | Input current | IIN | 0.7 | A |
| 04 | Rated power | W | 16 | W |
| 05 | UVC radiant output | Φe | 500 | mW |
| 06 | UVC wavelength | WLP | 270–280 | nm |
| 07 | Lifetime test | L70 | 5,000 | h |
The current AGLED-12G datasheet, drawing and SGS report are available for project review and quotation support.
OEM INTEGRATION REVIEW
Our application team matches simultaneous draw, pretreatment, UVT, pressure loss, G1 connection, power supply and service access to the complete POE layout.
Peak flow, UVT, turbidity, temperature and upstream treatment.
Pressure, connection size, flow direction, mounting and service clearance.
Supply voltage, host-appliance logic, flow activation and safe cable routing.
Match the exact model report and compliance documents to the target project.
MODEL-SPECIFIC EVIDENCE
The linked model report presents the organism, flow and water conditions behind this result; our team aligns them with the project duty.
Open model test reportThe report identifies the model, organism, flow and water conditions behind the performance result.
Performance reports and compliance documents are listed independently for straightforward review.
The table below lists the factory test items and acceptance criteria for the specific model.
The table below lists the factory test items and acceptance criteria for AGLED-12G.
Static pressure is maintained at 0.2 MPa for 5 minutes without air leakage.
Hydrostatic pressure is increased to 0.6 MPa within 5 minutes at a rate of ≤0.4 MPa/s and held for 15 minutes to check module water tightness.
Water pressure is raised to 0.8 MPa within 70 seconds at a rate of ≤0.4 MPa/s, held for 5 seconds and released; appearance, mechanical and electrical performance remain normal.
100,000 repeated cycles at 0–0.45 MPa with a 2-second pressure rise are used to observe module water tightness.
The water purification device operates powered on without water for 24 hours; the module remains undamaged and all functions remain available.
The sample is stored at −20°C ±2°C for 72 hours and recovered at room temperature for at least 1 hour; appearance remains normal, and UVC intensity and module operating current meet the drawing requirements.
The sample is stored at 50°C ±2°C for 72 hours and recovered at room temperature for at least 1 hour; appearance remains normal, and UVC intensity and module operating current meet the drawing requirements.
The module is placed in a 40°C, 85% RH test chamber for 168 hours without damage, and all functions remain available.
The packaged product is tested at 4 Hz (240 CPM) for 60 minutes to ISTA-2001; packaging, product surfaces and parts show no obvious damage, and product function remains normal.
At 35°C ±2°C, 5% NaCl and pH 6.5–7.2, the sample is exposed for 48 hours to GB/T 2423.17, rinsed and recovered; module components show no rust or obvious oxidation.
Packaging corners, edges and surfaces are dropped freely from a 1-metre platform; packaging, fixtures, product surfaces and parts meet the stated mechanical, electrical and appearance criteria.
Module hazardous-substance content is checked against the limit requirements of the EU RoHS directive.
DOCUMENT CENTER
Drawings, performance reports, installation documents and market files are organized by purpose for easier project review.
APPLICATION REVIEW
Share your peak flow, water quality and integration requirements. Our application team will match the model, configuration and supporting documents to your project.