RO water systems
A final POU microbial-control stage after the required filtration stages.
FLOW-SWITCH POU UVC LED MODULE
An integrated-flow-switch module for automated POU operation.
EC-12 combines an integrated flow switch with 12 V or 24 V supply options and 1/4-inch or 3/8-inch quick-connect configurations for POU appliances.
PRODUCT ROLE
EC-12 supports on-demand operation when water flows. Our application team matches the suitable flow, connection, voltage and optical-output option to the appliance.
APPLICATION FIT
A final POU microbial-control stage after the required filtration stages.
Automatic activation where peak draw and flow-switch behaviour fit the appliance.
Compact POU equipment using the confirmed quick-connect variant.
Integrated control for equipment builders after version, cable and terminal review.
ENGINEERING DATA
The current drawing, datasheet and manual are available for project review. Our team will align them with the quoted configuration.
Hydraulic & mechanical
Electrical & optical
| No. | Parameter | Symbol | Value | Unit |
|---|---|---|---|---|
| 01 | Input voltage | VIN | 12 / 24 | V |
| 02 | Input power | W | ≤4.8 | W |
| 03 | UVC radiation power | Φe | 85 / 115, variant-dependent | mW |
| 04 | UVC peak wavelength | WLP | 270–280 | nm |
| 05 | Lifetime test | L70 | ≥10,000 | h |
Available EC-12 options include 12 V / 24 V supplies, 1/4-inch / 3/8-inch connections and 85 / 115 mW optical outputs. Our application team will match the suitable combination to the appliance design and quotation.
OEM INTEGRATION REVIEW
Our application team aligns activation threshold, flow direction, tube size, pressure, power version, cable and terminal for the quoted configuration.
Peak flow, UVT, turbidity, temperature and upstream treatment.
Pressure, connection size, flow direction, mounting and service clearance.
Supply voltage, host-appliance logic, flow activation and safe cable routing.
Match the exact model report and compliance documents to the target project.
CIRCUIT REFERENCE
The supplied EC-12 document supports component protection, connection and host-system control design.
MODEL-SPECIFIC EVIDENCE
The linked EC-12 SGS report records the stated result under its named model, flow and water conditions. Our team can align the report with the quoted EC-12 configuration.
Open model test reportThe report identifies the model, organism, flow and water conditions behind the performance result.
Performance reports and compliance documents are listed independently for straightforward review.
The table below lists the factory test items and acceptance criteria for the specific model.
The table below lists the factory test items and acceptance criteria for EC-12, including the 1.2 MPa pressure and 1.04 MPa cyclic-pressure criteria.
Terminal-to-wire tensile force ≥30 N for 1 minute without loosening; welded wire-to-module tensile force ≥35 N without defects within 10 seconds.
1500 V / 50 Hz AC is applied between the live part and housing for 1 minute; the test sample remains undamaged.
Static pressure is held at 0.4 MPa for 5 minutes without air leakage.
Static water pressure is increased to 1.2 MPa within 5 minutes at a rate of ≤0.4 MPa/s and held for 15 minutes to check module water tightness.
10,000 repeated cycles at 0–1.04 MPa with a 2-second pressure rise are used to observe module water tightness.
The water purification device operates powered on without water for 24 hours; the module remains undamaged and all functions remain available.
The water-filled, blocked module is placed at −18°C for 48 hours and then thawed naturally; sealing performance remains normal.
The sample is stored at −30°C ±2°C for 72 hours and recovered at room temperature for at least 1 hour; appearance remains normal, and UVC intensity and module working current meet the drawing requirements.
The sample is stored at 50°C ±2°C for 72 hours and recovered at room temperature for at least 1 hour; appearance remains normal, and UVC intensity and module working current meet the drawing requirements.
The sample cycles 10 times between −30°C ±2°C and 85°C ±2°C with 30-minute holds and a 3-minute conversion time, then recovers at room temperature for at least 1 hour; appearance, UVC intensity and working current meet the drawing requirements.
The module is placed in a 40°C, 85% RH test chamber for 168 hours without damage, and all functions remain available.
The packaged product is tested at 4 Hz (240 CPM) for 60 minutes to ISTA-2001; packaging shows no obvious damage or deformation, the product surface and parts show no mechanical damage, and product function remains normal.
At 35°C ±2°C, 5% NaCl and pH 6.5–7.2, the sample is exposed for 48 hours to GB/T 2423.17, rinsed and recovered; module components show no rust or obvious oxidation.
Packaging corners, edges and surfaces are dropped freely from a 1-metre platform; packaging, fixtures, product surfaces and parts meet the stated mechanical, electrical and appearance criteria.
Module hazardous-substance content is checked against the limit requirements of the EU RoHS directive.
DOCUMENT CENTER
Drawings, performance reports, installation documents and market files are organized by purpose for easier project review.
APPLICATION REVIEW
Share your peak flow, water quality and integration requirements. Our application team will match the model, configuration and supporting documents to your project.